297 research outputs found

    No differences in in vivo kinematics between six different types of knee prostheses

    Get PDF
    Purpose: The aim of this study was to compare a broad range of total knee prostheses with different design parameters to determine whether in vivo kinematics was consistently related to design. The hypothesis was that there are no clear recognizable differences in in vivo kinematics between different design parameters or prostheses. Methods: At two sites, data were collected by a single observer on 52 knees (49 subjects with rheumatoid arthritis or osteoarthritis). Six different total knee prostheses were used: multi-radius, single-radius, fixed-bearing, mobilebearing, posterior-stabilized, cruciate retaining and cruciate sacrificing. Knee kinematics was recorded using fluoroscopy as the patients performed a step-up motion. Results: There was a significant effect of prosthetic design on all outcome parameters; however, post hoc tests showed that the NexGen group was responsible for 80% of the significant values. The range of knee flexion was much smaller in this group, resulting in smaller anterior-posterior translations and rotations. Conclusion: Despite kinematics being generally consistent with the kinematics intended by their design, there were no clear recognizable differences in in vivo kinematics between different design parameters or prostheses. Hence, the differences in design parameters or prostheses are not distinct enough to have an effect on clinical outcome of patients.Biomechanical EngineeringMechanical, Maritime and Materials Engineerin

    New fluoroscopic imaging technique for investigation of 6DOF knee kinematics during treadmill gait

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>This report presents a new imaging technique for non-invasive study of six degrees of freedom (DOF) knee kinematics during treadmill gait.</p> <p>Materials and methods</p> <p>A treadmill was integrated into a dual fluoroscopic imaging system (DFIS) to formulate a gait analysis system. To demonstrate the application of the system, a healthy subject walked on the treadmill at four different speeds (1.5, 2.0, 2.5 and 3.0 MPH) while the DFIS captured the knee motion during three strides under each speed. Characters of knee joint motion were analyzed in 6DOF during the treadmill walking.</p> <p>Results</p> <p>The speed of the knee motion was lower than that of the treadmill. Flexion amplitudes increased with increasing walking speed. Motion patterns in other DOF were not affected by increase in walking speed. The motion character was repeatable under each treadmill speed.</p> <p>Conclusion</p> <p>The presented technique can be used to accurately measure the 6DOF knee kinematics at normal walking speeds.</p

    Effects of methods of descending stairs forwards versus backwards on knee joint force in patients with osteoarthritis of the knee: a clinical controlled study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this study was to investigate the kinetic characteristics of compensatory backward descending movement performed by patients with osteoarthritis of the knee.</p> <p>Methods</p> <p>Using a three-dimensional motion analysis system, we investigated lower extremity joint angles, joint moments, joint force of the support leg in forward and backward descending movements on stairs, and joint force of the leading leg at landing in 7 female patients with osteoarthritis of the knee.</p> <p>Results</p> <p>Compared with the forward descending movement, knee joint angle, joint moment and joint force of the support leg all decreased in the backward descending movement. Joint force of the leading leg at landing was also reduced in the backward descending movement. In addition, we confirmed that the center of body mass was mainly controlled by the knee and ankle joints in the forward descending movement, and by the hip joint in the backward descending movement.</p> <p>Conclusions</p> <p>Since it has been reported that knee flexion angle and extensor muscle strength are decreased in patients with osteoarthritis of the knee, we believe that backward descending movement is an effective method to use the hip joint to compensate forthese functional defects. In addition, due to the decreased knee joint force both in the leading and support legs in backward descending movement, the effectiveness of compensatory motion for pain control and knee joint protection was also suggested.</p

    Classification of patients with knee osteoarthritis in clinical phenotypes: data from the osteoarthritis initiative

    Get PDF
    <div><p>Objectives</p><p>The existence of phenotypes has been hypothesized to explain the large heterogeneity characterizing the knee osteoarthritis. In a previous systematic review of the literature, six main phenotypes were identified: Minimal Joint Disease (MJD), Malaligned Biomechanical (MB), Chronic Pain (CP), Inflammatory (I), Metabolic Syndrome (MS) and Bone and Cartilage Metabolism (BCM). The purpose of this study was to classify a sample of individuals with knee osteoarthritis (KOA) into pre-defined groups characterized by specific variables that can be linked to different disease mechanisms, and compare these phenotypes for demographic and health outcomes.</p><p>Methods</p><p>599 patients were selected from the OAI database FNIH at 24 months’ time to conduct the study. For each phenotype, cut offs of key variables were identified matching the results from previous studies in the field and the data available for the sample. The selection process consisted of 3 steps. At the end of each step, the subjects classified were excluded from the further classification stages. Patients meeting the criteria for more than one phenotype were classified separately into a ‘complex KOA’ group.</p><p>Results</p><p>Phenotype allocation (including complex KOA) was successful for 84% of cases with an overlap of 20%. Disease duration was shorter in the MJD while the CP phenotype included a larger number of Women (81%). A significant effect of phenotypes on WOMAC pain (F = 16.736 p <0.001) and WOMAC physical function (F = 14.676, p < 0.001) was identified after controlling for disease duration.</p><p>Conclusion</p><p>This study signifies the feasibility of a classification of KOA subjects in distinct phenotypes based on subgroup-specific characteristics.</p></div

    Development and validation of a computational model of the knee joint for the evaluation of surgical treatments for osteoarthritis

    Get PDF
    A three-dimensional (3D) knee joint computational model was developed and validated to predict knee joint contact forces and pressures for different degrees of malalignment. A 3D computational knee model was created from high-resolution radiological images to emulate passive sagittal rotation (full-extension to 658-flexion) and weight acceptance. A cadaveric knee mounted on a six-degree-of-freedom robot was subjected to matching boundary and loading conditions. A ligamenttuning process minimised kinematic differences between the robotically loaded cadaver specimen and the finite element (FE) model. The model was validated by measured intra-articular force and pressure measurements. Percent full scale error between FE-predicted and in vitro-measured values in the medial and lateral compartments were 6.67% and 5.94%, respectively, for normalised peak pressure values, and 7.56% and 4.48%, respectively, for normalised force values. The knee model can accurately predict normalised intra-articular pressure and forces for different loading conditions and could be further developed for subject-specific surgical planning

    Damages of the tibial post in constrained total knee prostheses in the early postoperative course – a scanning electron microscopic study of polyethylene inlays

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Investigation of the risk of fracture of the polyethylene (PE) inlay in constrained total knee prostheses.</p> <p>Methods</p> <p>Three unused and seven polyethylene inlays that had been implanted in a patient's knee for an average of 25.4 months (min 1.1 months, max 50.2 months) were investigated using scanning electron microscopy (SEM). All inlays were of the same type and size (Genesis II constrained, Smith & Nephew). The PE surface at the transition from the plateau to the post was analyzed.</p> <p>Results</p> <p>The unused inlays had fissure-free surfaces. All inlays that had been implanted in a patient's knee already had distinct fissures at the front and backside of the post.</p> <p>Conclusion</p> <p>The fissures of the transition from the plateau to the post indicated a loading-induced irreversible mechanical deformation and possibly cause the fracture of the inlay.</p

    Severe axial vertebral rotation treated with a modified Boston brace: a case report

    Get PDF
    We report the case of a 13-year-old Caucasian girl suffering from severe axial rotation of the T5 to L4 vertebrae. The patient (initially examined during a school screening study) was at first considered to be suspicious of suffering from scoliosis due to a highly positive Adam's forward bending test. However, her radiographic evaluation revealed the existence of axial rotation in 12 of her vertebrae, without inclination in the sagittal and coronal planes. After an observation period of 12 months and due to the fact that both her physical appearance and the measured vertebral rotation deteriorated, the patient was given a modified thoracolumbar Boston brace that had an immediate positive derotational effect on all but two vertebrae. Twenty four months later, the progress of the vertebral rotation(s) seems to have been halted and most affected vertebrae appear to be stabilized in their new, 'post-brace', reduced position, with better results shown when the Boston brace is worn. The patient remains under constant medical observation. The application of a modified Boston brace seems to have served well (so far) a useful purpose for reducing and stabilizing this case of severe axial vertebral rotation, providing less deformity and (possibly) offering a better final cosmetic result
    corecore